Skip to main content

EPI Inline Products

Series AL40

epi

Description

The Eldridge Product, Inc. (EPI) AirLine Series AL40 Inline is the all new series of thermal mass flow meters designed to aid in the measurement and management of compressed airsystems’ consumption and usage. Low cost and offered in sizes from ¼” NPT to 2” NPT with extremely fast response time.

The AirLine Series AL40Flow Meters are compact In-Line style instruments. The CNC machined and anodized 6061-T6 aluminum flow section is specified to match the user’s flow conduit and is then plumbed directly into the process line. The Series AL40 features a thermal glass coated ceramic sensor for the ultimate infastresponse time. The sensing elements are mounted directly in the flow section for exposure to the process gas. All electronics are mounted integrally on the flow section in an aluminum NEMA 4X (IP66) enclosure.


EPI Series 7000 Inline Thermal Mass Flow Switch

EPI 2

Description

The Eldridge Product,Inc. (EPI) Inline style thermal mass flow switch series 7000 assembly includes the flow sensing element, temperature sensing element, bridge amplifier/signal output board, transmitter enclo­sure, and flow section. The flow section is typically specified to match the user’s flow conduit and is plumbed directly in the flow line. This design has the sensing elements mounted directly in the flow section for exposure to the process flow.

Inline flow switches are available in sizes from 1/4″ pipe through 4″ pipe and are provided with threaded male NPT ends as the standard mounting style. Optional end mounting styles may be specified, such as tube ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required. Pipe sizes in excess of 4″ require insertion style thermal mass flow switches.

All of EPI’s flow switches have two single-pole, double-throw relays for Hi/Hi, Lo/Lo and Hi/Lo capability. The contact closure is 5 amps @ 24 VDC and 115 VAC. Two LEDs are provided for verification that the Hi or Lo alarm has been triggered. The standard configuration has 316 Stainless Steel wetted parts (Hastelloy & Monel are also available) for a rugged, cleanable instrument designed for use in applications where corrosion, abrasion, high pressure or rough handling may be expected


EPI Series 8000-8100MP Inline Remote Thermal Mass Flow Meter

EPI3

Description

The Eldridge Product,Inc. (EPI) Inline style thermal mass flow meter series 800-8100MP includes a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1/4″ pipe through 4″ pipe or tube, and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Remote style thermal mass flow meters utilize two enclosures. One enclosure is mounted at the point of measurement on the flow section or on the probe assembly. This enclosure may be rated for either hazardous environments or for ordinary, non-hazardous environments, as necessary. The second (remote) enclosure is usually placed in a readily accessible location rated for non-hazardous conditions. (Contact the factory for information concerning remote explosion-proof enclosure). The remote enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly. Only a four-wire, twisted-pair cable is required to carry the input power and flow signal between the two enclosures.

Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller operated smart sensor technology preferentially heats one RTD; the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs. This increase is directly related to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.


EPI Series 8000-8100MPNH Inline Remote Thermal Mass Flow Meter

epi4

Description

The Eldridge Product,Inc. (EPI) Inline style thermal mass flow meter series 8000-8100MPNH  includes a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1/4″ pipe through 4″ pipe or tube, and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Remote style thermal mass flow meters utilize two enclosures. One enclosure is mounted at the point of measurement on the flow section or on the probe assembly. This enclosure may be rated for either hazardous environments or for ordinary, non-hazardous environments, as necessary. The second (remote) enclosure is usually placed in a readily accessible location rated for non-hazardous conditions. (Contact the factory for information concerning remote explosion-proof enclosure). The remote enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly. Only a four-wire, twisted-pair cable is required to carry the input power and flow signal between the two enclosures.

Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller operated smart sensor technology preferentially heats one RTD; the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs. This increase is directly related to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.


EPI Series 800HPN High Purity Thermal Mass Flow Meter

epi5

Description

The Eldridge Product,Inc. (EPI) Inline Thermal Mass Meter Series 800HPN includes a feature set designed for a variety of Ultra High Purity and High Purity applications including Semiconductor & Displays, Pharmaceutical, Biotechnology, Food & Beverage, and other processes that require a clean hygienic flow meter.

Master-Touch Series 800HPN Flow Meters are In-line style instruments with all electronics mounted integrally on the flow section in a Type 4X, IP66 enclosure. All input power and signal output connections are accessible through this double-sided enclosure. The Series features a VCR style sensor for easy removal and cleaning. The internal wetted surfaces may be electro-polished to either a 10 Ra or 25 Ra surface finish. Inlet flow conditioning plates are optionally available on flow sections from ¾” to 6”. Mounting is via butt weld ends.

Optional end configurations include – Tri-Clamp style ends or male VCR style ends for ½”, ¾” or 1” tubes.

A 2-line, 16-character LCD display with a 4-button keypad, displays the flow rate, totalized flow total, gas temperatures, electronics temperatures, sensor milliwatts, event/alarm relay status. It also provides access to the menuing system for change of user accessible variables. Included are 0–5 VDC and 4-20 mA outputs proportional to flow, as well as RS232; RS485; Modbus RTU; BACnet communications.


EPI Series 800HPX Inline High Purity Thermal Mass Flow Meter

EPI6

Description

The Eldridge Product,Inc.(EPI) Inline High Purity Thermal Mass Meter Series 800HPX includes a feature set designed for a variety of Ultra High Purity and High Purity applications including Semiconductor & Displays, Pharmaceutical, Biotechnology, Food & Beverage, and other processes that require a clean hygienic flow meter.

Master-Touch Series 800HPX Flow Meters are In-line style instruments with all electronics mounted integrally on the flow section in a Type 4X, IP66 enclosure. All input power and signal output connections are accessible through this double-sided enclosure. The Series features a VCR style sensor for easy removal and cleaning. The internal wetted surfaces may be electro-polished to either a 10 Ra or 25 Ra surface finish. Inlet flow conditioning plates are optionally available on flow sections from ¾” to 6”. Mounting is via butt weld ends.

Optional end configurations include – Tri-Clamp style ends or male VCR style ends for ½”, ¾” or 1” tubes.

A 2-line, 16-character LCD display with a 4-button keypad, displays the flow rate, totalized flow total, gas temperatures, electronics temperatures, sensor milliwatts, event/alarm relay status. It also provides access to the menuing system for change of user accessible variables. Included are 0–5 VDC and 4-20 mA outputs proportional to flow, as well as RS232; RS485; Modbus RTU; BACnet communications.


EPI Series 8600-8700MP Inline Thermal Mass Flow Meter

EPI7

Description

The Eldridge Product,Inc.(EPI) Inline Thermal Mass Meter series 8600 - 8700 MP Series include a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1/4″ pipe through 4″ pipe or tube, and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Integral style thermal mass flow meters have all of the electrical components and connections located within one enclosure. This enclosure may be rated for either hazardous environments (MP Series) or for ordinary, non-hazardous environments (MPNH Series), as necessary. The enclosure is mounted directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller operated smart sensor technology preferentially heats one RTD; the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs. This increase is directly related to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.


EPI Series 8600-8700MPNH Inline Thermal Mass Flow Meter

EPI8

Description

The Eldridge Product,Inc. (EPI) MPNH Series 8600 - 8700 flow meters includes a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly in the flow section for exposure to the process gas. Our inline style thermal mass flow meters are available in sizes from 1/4″ pipe through 4″ pipe or tube, and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Integral style thermal mass flow meters have all of the electrical components and connections located within one enclosure. This enclosure may be rated for either hazardous environments (MP Series) or for ordinary, non-hazardous environments (MPNH Series), as necessary. The enclosure is mounted directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). The platinum sensing element wire is encapsulated in a 316 Stainless Steel sheath or, if specified, a Hastelloy C sheath. Our microcontroller operated smart sensor technology preferentially heats one RTD; the other RTD acts as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs. This increase is directly related to the gas molecular rate of flow. Our sensors are temperature compensated for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.


 EPI Series 9100MP Inline Remote Flow Averaging Tube (FAT)

EPI9

Description

The Eldridge Product,Inc. (EPI)  Inline style thermal mass flow meter series 9100MP include a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly on the flow section for exposure to the process gas. Our inline style flow averaging thermal mass flow meters are available in sizes from 2″ pipe through 4″ pipe and are provided with flanged end configurations, as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Remote style thermal mass flow meters utilize two enclosures. One enclosure is mounted at the point of measurement on the flow section or on the probe assembly. This enclosure may be rated for either hazardous environments or for ordinary, non-hazardous environments, as necessary. The second (remote) enclosure is usually placed in a readily accessible location rated for non-hazardous conditions. (Contact the factory for information concerning remote explosion-proof enclosure). The remote enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Our patented Flow Averaging Tubes™ (FAT™) use the principle of convective heat transfer to directly measure mass flow, and are well suited to most applications with limited available straight run. In many installations, the up-stream straight run can be reduced to three diameters. The probe has a number of large diameter inlet ports along the length of the upstream impact surface. The pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas returns to the main flow stream through the ports located near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still some require minor adjustment to achieve the best accuracy.


EPI Series 9100MPNH Inline Remote Flow Averaging Tube (FAT) Thermal Mass Flow Meter

EPI10

Description

The Eldridge Product,Inc. (EPI) Inline style thermal mass flow meter series 9100MPNH include a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly on the flow section for exposure to the process gas. Our inline style flow averaging thermal mass flow meters are available in sizes from 2″ pipe through 4″ pipe and are provided with flanged end configurations, as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Remote style thermal mass flow meters utilize two enclosures. One enclosure is mounted at the point of measurement on the flow section or on the probe assembly. This enclosure may be rated for either hazardous environments or for ordinary, non-hazardous environments, as necessary. The second (remote) enclosure is usually placed in a readily accessible location rated for non-hazardous conditions. (Contact the factory for information concerning remote explosion-proof enclosure). The remote enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Our patented Flow Averaging Tubes™ (FAT™) use the principle of convective heat transfer to directly measure mass flow, and are well suited to most applications with limited available straight run. In many installations, the up-stream straight run can be reduced to three diameters. The probe has a number of large diameter inlet ports along the length of the upstream impact surface. The pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas returns to the main flow stream through the ports located near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still some require minor adjustment to achieve the best accuracy.


EPI Series 9700MP Inline Flow Averaging Tube (FAT) Thermal Mass Flow Meter

EPI11

Description

The Eldridge Product,Inc. (EPI) Inline style thermal mass flow meter series 9700MP includes a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line. This design has the sensing elements mounted directly on the flow section for exposure to the process gas. Our inline style flow averaging thermal mass flow meters are available in sizes from 2″ pipe through 4″ pipe and are provided with flanged end configurations, as required. Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters.

Integral style thermal mass flow meters have all of the electrical components and connections located within one enclosure. This enclosure may be rated for either hazardous environments (MP Series) or for ordinary, non-hazardous environments (MPNH Series), as necessary. The enclosure is mounted directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Our patented Flow Averaging Tubes™ (FAT™) use the principle of convective heat transfer to directly measure mass flow, and are well suited to most applications with limited available straight run. In many installations, the up-stream straight run can be reduced to three diameters. The probe has a number of large diameter inlet ports along the length of the upstream impact surface. The pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas returns to the main flow stream through the ports located near the sensing elements. Anomalies in the actual flow profile or installations in non-circular ducts may still some require minor adjustment to achieve the best accuracy.


EPI ValuMass™ 400 Inline Thermal Mass Flow Meter

epi12

Description

The Eldridge Product, Inc. (EPI) ValuMass™ Series 400 offer another lower cost option for many flow applications with the high value associated with all of EPI’s flow measurement instrumentation.

ValuMass™ flow meters include a robust feature set: 0 – 5, 10 VDC, 4 – 20mA, RS485 Modbus RTU and optional 0 – 1 kHz outputs (proportional to the gas mass flow rate); an RS232C port; 16-bit linearization technology for flow rate accuracy; a fully programmable relay; and rugged construction of 316/316L stainless steel wetted parts. An optional 2-line, 16-character backlit LCD displays the flow rate and the elapsed total readouts.

ValuMass™ inline and insertion flow meters accommodate virtually all installation requirements. The Series 400 inline style flow­ meters are available for line sizes from ¼” to 2”. The 3 ½” long flow sections have MNPT ends as standard for easy mounting in the process line. Other end fittings are available. ValuMass™ flow meters accept 24VDC, 115VAC or 230VAC input power as specified at the time of purchase.


EPI ValuMass™ 500 Inline Thermal Mass Flow Meter

EPI13

Description

The Eldridge Product, Inc. (EPI) ValuMass™ Series 500 Flow meter  is a proven leader in gas flow measurement. Our Master-Touch™ thermal dispersion gas mass flow meters and patented Flow Averaging Tubes set the standard for innovation, performance and reliability. Now our Series 500 ValuMass™ flow meters offer a lower cost option for many flow applications with the high value associated with all of EPI’s flow measurement instrumentation.

The Series 500 ValuMass™ flow meters include 16-bit linearization technology for excellent flow rate accuracy and rugged construction of 316L stainless steel wetted parts.

If you require further information on this product or would like a quotation, please contact dp-flow on: