Air Duct/HVAC Air Flow
[widgetkit id="61" name="Air Duct & HVAC Air Flow Meters"]
Eldridge Products, Inc.’s patented* Flow Averaging Tubes (FAT™) were designed to provide accurate flow measurement in large pipes and ducts without the expense and complexity of traditional multipoint systems by offering a cost-effective solution for Heating, Ventilation, and Air Conditioning (HVAC) and Variable Air Volume (VAV) applications. Because they also provide accurate, repeatable readings in applications with very limited upstream straight run this list has been expanded by our customers over the years to now include almost any gas measurement requirement, with particular emphasis on natural gas usage and submetering.
The Master-Touch™ FAT™ probes utilize a flow averaging tube to give a stable flow signal in applications where the flow profile is less than ideal, such as downstream of a bend, valve, tee or obstruction. The flow averaging tube has a number of large diameter (0.125”) inlet ports along the length of the upstream impact surface. The impact pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas flow then passes back into the main flow stream through the gas return ports located near the flow sensing elements.
Anomalies in the actual flow profile or installations in non-circular ducts may require a C-Factor adjustment for the best accuracy. The velocity impact pressure follows a square root function. Therefore, the average velocity pressure in the FAT™ probe may vary slightly from the average of the velocities at each inlet port. The Master-Touch™ electronics easily accommodate the C-Factor adjustment.
The FAT technology is available in the same range of physical configurations as the other Eldridge Products' instruments. Inline style averaging tubes are available for pipe sizes 2" and greater with flanged ends; insertion style FAT probes can be as small as 2" or as large as necessary (90+" to date!). Integral and remote electronics with approvals for hazardous or non-hazardous locations allow the FATs to meet most installation requirements.
The Master-Touch™ MP Series Flow Averaging Tubes are approved by CSA/CUS, ATEX, IECEx and KOSHA for use in hazardous area locations.
The Master-Touch™ MPNH Series Flow Averaging Tubes are approved by CSA/CUS for use in general purpose (Ordinary) area locations.
MPNH Series Flow Averaging Tubes
*U. S. Patent No. 6,883,389 Other U.S. & foreign patents pending
Specifications
Linear signal output | Flow: 0–5 VDC & 4–20 mA Temperature: 0–5 VDC & 4–20 mA |
Relay Output | Two 1-amp @ 30 VDC, user-selectable alarm functions |
Signal Interface | LCD (flow rate, flow total, gas temperature) RS232 & RS485 Modbus RTU Optional HART or Profibus DP |
Accuracy including linearity (Ref.: 21°C): | ±(1.0% of Reading + 0.5% of Full Scale + GTC) |
Repeatability | ± 0.2% of Full Scale |
Sensor response time | 1 second to 63% of final value |
Turn down ratio | 100:1 @ 15,000 SFPM/76 NMPS minimum FS |
Ambient electronics temperature range | -40° to 120°F (-40° to 50°C) |
Gas temperature range | 40° to 150°F (5° to 65°C) |
Gas temperature coefficient (GTC) | 0.05% Full Scale/°C @ 40° to 100°F (5° to 40°C) 0.10% Full Scale/°C @ 100° to 150°F (40° to 65°C) |
Gas pressure effect | Negligible over ±20% of absolute calibration pressure |
Pressure rating maximum: | |
Inline flowmeters | 500 PSI Std., >500 special |
Insertion flowmeters | |
.500” OD | 125 PSI Std., >125 special |
.750” OD | 55 PSI Std., >55 special |
1.000” OD | 30 PSI Std., >30 special |
Transmitter power requirements | 5 Watts or less |
Input power requirement | 24VDC @ 250mA 115 VAC 50/60 Hz optional 230 VAC 50/60 Hz optional |
RAM Back-up | Lithium Battery, 2.5–3.5v, >10 years |
Wetted materials: | 316SS, including sensor |
Standard temperature & pressure (STP) | 70°F & 29.92" Hg |
(Air .075 lb/cubic foot) | |
NIST traceable calibration | Standard |
Specifications subject to change without notice.
Approval
MP Series Flow Transmitter — |
For use in hazardous area locations
|
MP Series Remote Enclosure — | For use in Ordinary(Non-Hazardous) area locations: Type 4X, IP66 |
Optional ACEX/DCEX |
For use in hazardous area locations CSA/CUS, ATEX, IEC Ex, KOSHA |
MPNH Series — | For use in Ordinary(Non-Hazardous) area locations: Type 4X, IP66 |
If you require further information on this product or would like a quotation, please contact dp-flow on:
email: sales@dp-flow.co.uk
sales +44(0)1608 544222
Supplied by DP-Flow