Accutech TM10 Wireless Turbine Meter Totaliser Field Unit

The Accutech™ TM10 wireless turbine meter field unit measures the volumetric flow rate of liquids or gases by detecting the frequency of pulses generated with a standard turbine meter (not included) and applying a user-configured proportional “K” factor. A 22-point correction curve can be used for custom calibration of the turbine meter. The unit provides two principal outputs: flow rate and totalised flow measurements.

Key Facts and Features:

  • Accutech TM10 Wireless Turbine Meter Totaliser

    Sensor Type: Turbine Meter Totaliser
  • Frequency Range: 900 MHz and 2.4 GHz license-free bands
  • Turbine Meter Frequency Range: 4 Hz...10 KHz
  • Accuracy: Flow rate accurate to ±0.01% of reading (excluding turbine meter and pickup)
  • Physical Connection: 1 in. female NPT connection to Turbine Meter
  • Magnetic Pickup: Two-wire connector supplied
  • Input Sensitivity:
  • 3.5 mV RMS @ 5 Hz
  • 3.5 mV RMS @ 50 Hz
  • 5 mV RMS @ 500 Hz
  • 45 mV RMS @ 5000 Hz
  • Battery Life: Up to 10 years, depending on configuration
  • Durable Design: Housed in a weather-resistant NEMA 4X enclosure with options for remote sensor and antenna.
  • User-Friendly: Integrated LCD display with membrane-switch buttons; display provides flow, total, and detected error messages.
  • Self-Diagnostics: Continuous monitoring of operation with notification of out-of-spec parameters.
  • Local Configuration Interface: Configure sampling and RF parameters using membrane-switch buttons.
  • Remote Configuration: Via Accutech Manager software for network-wide monitoring and management.
  • Network Capacity: Supports up to 100 field units per base radio and 256 base radios per network.
  • Low Battery Notification: Indicates the need to replace the battery approximately one month in advance.

Benefits:

  • Wireless Flexibility: Integrated frequency-hopping spread-spectrum transceiver for robust communication over distances up to 3000 ft (1000 m).
  • Battery Efficiency: Configurable sampling and transmission rates extend battery life.
  • Scalability: Supports up to 100 field units per base radio and 256 base radios per network.

Applications:

  • Volumetric flow measurement of liquids and gases
  • Industrial flow monitoring
  • Any industry requiring precise and reliable flow rate and totalised flow measurements

Technical Specifications:

Operating Temperature:

    • Electronics: -40...+85 °C (-40...+185 °F)
    • Display: -40...-20 °C (-40...-4 °F) with reduced visibility
    • Humidity: 0...95%, non-condensing
    • Materials: 316L stainless steel fittings, epoxy-coated aluminum enclosure
    • Power: Self-contained with 1 D-cell Lithium Thionyl battery

Communication:

    • 900 MHz: 902...928 MHz band, data rates of 19.2 kbps and 76.8 kbps
    • 2.4 GHz: 2400...2483.5 MHz band, data rates of 50/100 kbps
    • Electronic Accuracy and Stability: Applies to pulse frequencies above low cut-off of 4 Hz
    • Environmental Testing: Tested per IEC 60068-2-6 (vibration) and IEC 60068-2-27 (shock)
    • Electromagnetic Compatibility: Operates within specification in fields from 80...1,000 MHz with field strengths to 30 V/m. Meets EN 50082-1 General
    • Output Resolution: 24-bit analog-to-digital conversion